Turbofan oven error codes
What Moffat Turbofan digital and E33T touchscreen error codes mean, safe checks to try first, and when to call a technician.
Error on the display and service starting soon? Call 0800 90 60 30. Calls are answered 24 hours, 7 days. Technician cover runs 7 days, with after-hours emergency cover. Our target for emergency responses is two hours. It's a target, not a guarantee, and it depends on workload at the time.
Turbofan is Moffat's convection oven brand. Ovens with a digital display (the 30D series) and ovens with a touchscreen (the E33T) show different messages. Before you switch off, photograph the display and note the model from the rating plate, then use the section that matches your oven. CES Wellington are service agents for Moffat and Turbofan. See all brand pages on error codes.
Turbofan 30D series digital ovens (E32D5)
| Code | What it means | What you can safely do |
|---|---|---|
| dor | The door isn't fully closed, or the door switch is faulty. The oven won't heat while dor is showing. | Check a tray or the door seal isn't stopping the door closing, then close it fully. If dor stays with the door shut, call us. |
| Err 001 | Oven temperature probe failure. | Switch the oven off and call us. Leave the panels on. |
| Err 003 | Fan motor thermal cut-out has tripped. | Switch the oven off and call us. Leave the panels on. Don't keep restarting it. |
| CP flashing (alarm sounding, programme paused) | The programme needs the core temperature probe, and it isn't connected, or the core probe is faulty. | Plug the core probe into the control panel. If it still flashes with the probe connected, the probe may need replacing. Call us. |
If CP doesn't show when the core probe is plugged in, the core probe may be faulty.
Source: Moffat Turbofan 30D Series E32D5 Installation and Operation Manual (237457-1, Moffat Ltd, 2014), Fault Finding. Other Turbofan digital models may show different codes. If your code isn't listed, photograph it and call us.
Turbofan E33T touchscreen ovens
On the E33T, an error shows as a message on the screen, usually with "Call For Service".
| Message on screen | What it means | What you can safely do |
|---|---|---|
| Cavity Probe Error | The oven temperature probe is open or short circuit. | Switch the oven off and call us. Leave the panels on. |
| Cavity High Temperature Error | The oven cavity has gone above 338°C. There's a fault in the heating control circuit. | Switch the oven off at the wall or isolator if it's safe to do so. Call us. Leave the panels on. |
| No Heat Error | The oven hasn't detected a temperature rise within 15 minutes. | Call us. Leave the panels on. |
| I/O Error | Touch controller fault. | Call us. Leave the panels on. |
| Fan Error | The fan motor thermal protection has tripped. | Switch the oven off and call us. Don't keep restarting it. |
| Core Probe Error | The core temperature probe is short circuit. | You may still be able to cook without the core probe. Call us to have it checked. |
| Configuration Files Invalid / Attempting to Restore | The SD card isn't seated properly, or there's a software or controller fault. | Call us. Don't remove the SD card yourself unless you've been trained to. |
Source: Moffat Turbofan E33T Convection Oven Service Manual, Amendment 9 (Moffat Ltd, November 2018), section 4, Fault Finding.
Safe checks to try first
- Door: closed fully, with no tray or seal stopping it.
- Power: the oven is switched on at the wall or isolator, and the site breaker hasn't tripped.
- Core probe: plugged in properly if the programme uses it.
- Air flow: nothing is blocking the oven vent, and the oven isn't overloaded.
Leave the panels on. There are live electrical parts inside. If you smell burning or the oven is overheating, switch off at the wall or isolator if it's safe to do so, and call us.
When to call a technician
- The safe checks above don't clear the code.
- The code is a probe, fan motor, heating or controller fault.
- The oven trips the power, smells of burning or won't heat.
FAQ
What does Err 003 mean on a Moffat Turbofan oven?
On a Turbofan 30D series digital oven such as the E32D5, Moffat's manual lists Err 003 as "Motor Thermal Cut-Out tripped". The fan motor has overheated and its protection has cut out. Switch the oven off, don't keep restarting it, and call 0800 90 60 30.
What does Err 001 mean on a Turbofan?
Err 001 means the oven temperature probe has failed. The oven can't control its temperature properly. Switch it off and call us.
My Turbofan shows "dor". What does that mean?
The oven thinks the door is open. Check a tray, rack or the door seal isn't stopping the door closing, then close it fully. If dor stays on with the door shut, the door switch may need adjusting or replacing. Call us.
What does "Fan Error" mean on a Turbofan E33T?
The fan motor's thermal protection has tripped. Switch the oven off and call us. Don't keep restarting it.
Do you repair Moffat and Turbofan ovens?
Yes. CES Wellington are service agents for Moffat and Turbofan. Our factory-trained technicians (where applicable) work on Turbofan convection and combi ovens. See Moffat Turbofan oven repairs and commercial oven repairs. We're also service agents for Blue Seal. We don't do gas work in Palmerston North, Pahiatua, Masterton, Carterton or the Wairarapa.
Error still showing?
Call 0800 90 60 30, email service@cesw.co.nz or book a job. The line is answered 24 hours, 7 days. Our work is covered by a 90-day parts and labour warranty.